2025, №3

сс. 22-33

Phase Behavior of the Binary System «Freon R404a - Acetone» and SCF Extraction of Acetone from an Aqueous Solution with Freon R404a

2025, №3

сс. 22-33

Цитировать

Z.I. Zaripov, R.R. Nakipov, R.A. Usmanov, A.U. Aetov, F.M. Gumerov

Key words: binary system, phase behavior, supercritical fluid state, extraction, process efficiency

The article presents the results of an experimental study of the phase behavior of the binary mixture «freon R404A-acetone»» carried out at temperatures of 356.15 K, 372.15 K and 392.15 K. I—II type of phase behavior according to the Williams classification is established. The article presents the results of a study of the supercritical fluid extraction process as applied to the problem of extracting acetone from its aqueous solution of 3.5% and 10 % concentration. In the process carried out at a temperature of 356.15 K (83 °C), an increase in the efficiency of the extraction process was established as the pressure approaches its critical value for the designated binary system.